Refine your search:     
Report No.
 - 
Search Results: Records 1-4 displayed on this page of 4
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Absolute neutron emission measurement in burning plasma experiments

Nishitani, Takeo; Ishikawa, Masao; Kondoh, Takashi; Kusama, Yoshinori; Asai, Keisuke*; Sasao, Mamiko*

AIP Conference Proceedings 988, p.267 - 274, 2008/04

no abstracts in English

Journal Articles

Spectroscopic measurement system for ITER divertor plasma; Impurity influx monitor (divertor)

Sugie, Tatsuo; Ogawa, Hiroaki; Kasai, Satoshi*; Kusama, Yoshinori

AIP Conference Proceedings 988, p.218 - 221, 2008/04

The detailed design of the Impurity Influx Monitor (divertor) has been carried out to provide the measurement capability in the harsh environment. The potential damaging effects for the first mirrors mounted close to the plasma are the formations of coatings of impurities and the deposition of the dust. Mitigating measures to minimize the degradation of their performance by these effects, such as changes in the reflectivity, are adopted: for example, the plasma is viewed through a small aperture, and baffle plates are inserted in front of the first mirrors. However, it will not be possible to prevent the degradation completely. It is important to know the change of the sensitivity of the optical systems. It is not feasible to install a light source in the vacuum chamber of ITER during operations and so an alternative method is needed. The in-situ calibration system using a micro retro-reflector array has been developed as a possible method.

Journal Articles

Development in diagnostics application to control of advanced tokamak plasma

Koide, Yoshihiko

AIP Conference Proceedings 988, p.413 - 419, 2008/03

An economically attractive DEMO requires a steady-state plasma with high bootstrap-current fraction fBS and high normalized beta. Development in diagnostic application to control of such advanced tokamak plasma is in progress worldwide, which will be discussed in this talk. For example, plasmas with a fraction of DEMO-relevant fBS of 70% have been sustained for 8s in JT-60 by real-time control of toroidal plasma flow based on the current profile measurement by which moderate relaxation of pressure gradient is induced, resulting into avoidance of collapse triggered at integer q$$_{min}$$ surfaces. In this experiment, change in the q value as a response to the pressure-gradient control was found to become big in the high fBS regime. Issues on (1) application of the present-day control methods to DEMO with self-heating, and (2) limitation of port space for the advanced control to keep a sufficient tritium-breeding ratio are also addressed.

Journal Articles

Development of fast measurement system of neutron emission profile using a digital signal processing technique in JT-60U

Ishikawa, Masao; Itoga, Toshio*; Okuji, Toshio*; Nakohostin, M.*; Shinohara, Koji; Baba, Mamoru*; Nishitani, Takeo

AIP Conference Proceedings 988, p.295 - 298, 2008/03

A line-integrated neutron emission profile is routinely measured using Stilbene neutron detector in JT-60U tokamak. Although the SND has many advantages as a neutron detector, the maximum count rate is limited up to 10$$^{5}$$ cps due to the analog pulse shape discrimination (PSD) circuit. To overcome this issue, a digital signal processing (DSP) system using a flash ADC has been developed In this system anode signals from photomultiplier of the SND are directory stored and digitized. Then, the PSD between neutrons and $$gamma$$ rays is performed using software. The DSP system has been installed in the vertical neutron collimator system inJT-60U and applied to deuterium experiments. It is confirmed that the PSD is sufficiently performed and collimated neutron flux is successfully measured with count rate up to 10$$^{6}$$ cps without the effect of pileup of detected pulses.

4 (Records 1-4 displayed on this page)
  • 1